Product details
Service creates value·Brand gives life
Thermal oil heater series
View the technical parameters and selection FAQs of thermal oil heaters →
180KW double-layer thermal oil heater (front)
180KW double-layer thermal oil heater (left view)
180KW double-layer thermal oil heater (right view)
10KW thermal oil heater
38KW thermal oil heater
80KW thermal oil heater
96KW thermal oil heaterSchematic diagram
Thermal Oil HeaterTechnical requirements:
1. Voltage: 220V/380V
2. Heating power: customized according to requirements
3. Barrel material: carbon steel
4. Temperature layer material: aluminum silicate wool
Thickness: determined according to temperature
Thermal oil heater working flow chartAir heater series
View air heater technical parameters and selection FAQ →
120KW steam heater
280KW air heater
80KW air heater
10KW nitrogen heater
4.0MPa 900° air heater
120KW(316L) air heaterSchematic diagram
Industrial Air HeaterTechnical requirements:
1. Voltage: 220V/380V
2. Power: customized according to requirements
3. Heating element material: stainless steel/carbon steel
Barrel material: carbon steel
4. Temperature range: customized according to requirements
5. Thickness of thermal insulation cotton: customized according to temperature requirements
Air duct heater series
View the technical parameters and selection FAQs of air duct heaters →
60KW air duct heater
56KW air duct heater
90KW air duct heater
160KW air duct heater
240KW air duct heater
60KW air duct heater
180KW air duct heater
30KW air duct heaterSchematic diagram
Duct HeaterTechnical requirements:
1. Voltage: 220V/380V
2. Power: customized according to requirements
3. Heating element material: stainless steel/carbon steel
Barrel material: carbon steel
4. Temperature range: customized according to requirements
5. Thickness of thermal insulation cotton: customized according to temperature requirements
Industrial Oven Series
View oven technical parameters and frequently asked questions about selection →
35m drying tunnel (Model: SQ-H-L-300)
5-meter drying tunnel (Model: SQ-H-L-100)
Hot air circulation oven (Model: SQ-H-X-R-300)
Hot air circulation oven (Model: SQ-H-X-R-200)
Double-chamber hot air circulation oven (Model: SQ-H-X—240)
Single door oven (Model: SQ-H-X-120)Oil and water heater series
Mobile box heater
120KW asphalt heater
220KW superheated steam heater
240KW diesel heater
130KW water heater
98KW heavy oil heater
30KW Lubricating Oil Heater
30KW asphalt heaterSchematic diagram
Heavy oil heater-main view
Heavy oil heater - top view
Asphalt heater - front view
Asphalt heater - side view
Asphalt heater - top viewTechnical requirements:
1. Voltage: 220V/380V
2.Hot box material: carbon steel/stainless steel
3. Heating tube material: customized on demand
4. Power: customized according to requirements
5. Heating temperature: customized on demand
Heating element series



ceramic heater

Cast aluminum heater

mica heater

cast copper heater

Mixer series
Height adjustable mixer
Mobile mixer
Bottom entry blender
Rubber lined mixer
900 degree high temperature mixer
Mobile mixer
side entry mixerMixing tank series
1000L jacketed heating mixing tank (Model: SQ-J-Z-60)
1500L electric heating mixing tank (model: SQ-J-D-120)
500L dosing mixing tank (Model: SQ-J-Y-7.5)
5000L stainless steel reactor (model: SQ-F-4-7.5KW)Stainless steel reactor: adopts packing (or) mechanical sealing, etc., and can use electric heating, hot water heating, thermal oil circulation heating, external (inner) coil heating, etc. The cooling method is jacket cooling and coil cooling in the kettle. Products are widely used in petroleum, chemical, pharmaceutical, food and other industries.
Decontamination remover series
DN500 vertical dirt remover
DN200 desander
DN600 horizontal dirt remover
DN900 horizontal dirt remover
DN800 cyclone dirt removerThe cyclone separator uses the centrifugal principle, completely breaking through the traditional concept of filter cleaning, thereby ensuring a small and balanced resistance in the pipeline system, and the system can discharge sewage without shutting down. It is most suitable for removing solid impurities such as sand, stones, and pipe wall peelings in the pipeline to ensure the normal operation of the system.
DN1000 fully automatic dirt removerThe use of DCS distributed control method (using digital signal remote transmission) effectively saves a lot of human and financial resources, and the entire control system is convenient and simple to operate. Greatly reduce investment costs in user project construction
Storage tank series
50m³ heavy oil storage tank
20m³ silo
30m³ oil storage tankFilter series
activated carbon filter
quartz sand filter
anthracite filter
Manganese sand filter
multi-media filter
Precision filter
Mixed ion exchanger
cation exchanger
anion exchangerWater distribution device series
Water distributor-side view
Water distribution device - face to face
Cylinder sub-rear view
Cylinder sub-side viewSchematic diagram
Technical requirements for water distributors:1. Barrel size: customized as needed
2. Barrel thickness: customized as required
3. Barrel material: carbon steel/Q345R
Group control thermal automatic system
CRJ-2D group control thermal automatic system
Calibration furnace
Standard oil tank/low temperature tank
Actual sample of group control thermal automatic systemSchematic diagram
CRJ-2D group control thermal automatic system structure:The operator can conveniently use the mouse to operate the entire process under any operating system. The microcomputer system displays the temperature control curve, temperature, calibration time and other parameters of the calibration furnace (or oil tank, low temperature tank, etc.) in real time. The system performs data processing in full compliance with the current national metrological verification regulations, and can print various record forms and verification certificates, and can also retain the original records for future reference. The system fully realizes the automation of the thermocouple and thermal resistance calibration process, namely: automatic temperature control, automatic calibration, automatic data processing, automatic printing of calibration results, and automatic saving of temperature rise curves. The operator's labor intensity is greatly reduced and the quality of the verification work is improved. This device also provides the system's certification program and data file management program, which facilitates the operator's archiving, retrieval and query of the system's certification and calibration results.